A 3-D coherent Doppler lidar system, developed by Mitsubishi Electric Co. (Tokyo, Japan), was installed on the rooftop of A-building of Fukuoka University (33.55 °N, 130.37 °E, 55 m above sea level) in Fukuoka city, and continuous 3-D wind and aerosol (SNR) measurements over the Fukuoka urban area (over the Fukuoka plain) have been conducted there since Nov 2016.
Technical specifications of 3-D Doppler lidar system | |
---|---|
Laser | DFB-Er doped fiber laser (Yb; YAG) |
Wavelength | 1.54 µm |
Pulse energy | 1.0 mJ/pulse |
Pulse repetition rate | 4000 Hz (average power: 4W) |
Pulse width | 200 ns |
Telescope diameter (effective) | 120 mm |
Range resolution | 30 m/ 60 m |
Measurable distance | up to 6 km/ 12 km (200 range bins) |
Data archive (after Nov 2018): http://www.se.fukuoka-u.ac.jp/takashima/dlidar_test/
Data archive (until Aug 2018): http://www.se.fukuoka-u.ac.jp/takashima/dlidar/
*If you would like to use any images on this web page, please contact us at the following e-mail address: hisahiro (at) fukuoka-u.ac.jp
Water level of chiller/room temp & RH: http://www.se.fukuoka-u.ac.jp/takashima/dlidar/cam/